FMU30-10A1/0 FMU30-AAHEABGHF Endress+Hauser Instruments FMU30
Manufacture: | Endress+Hauser | Product No.: | FMU30-AAHEABGHF |
---|---|---|---|
Approval: | Non-hazardous Area | Display; Operation: | Envelope Curve Display On Site; Push Button |
Electrical Connection: | Gland M20, IP68 | Process Connection: | Thread ISO228 G2, PP |
Gross Weight: | 0.944 Kilogram | Country Of Origin: | Germany |
Highlight: | FMU30-10A1/0 Endress+Hauser Instruments,Endress+Hauser Instruments FMU30,endress hauser fmu30 |
FMU30-10A1/0 FMU30-AAHEABGHF Endress+Hauser Ultrasonic measurement Time-of-Flight Prosonic FMU30
SPECIFICATIONS:
1. Approval: AA Non-hazardous area
2. Display; Operation: H Envelope curve display on site; push button
3. Electrical Connection: E Gland M20, IP68
4. Sensor; Max Range; Blocking Distance: AB 2"; 8m liquid/ 3.5m solid; 0.35m
5. Process Connection: GHF Thread ISO228 G2, PP
Specs at a glance
1. Accuracy
+/- 3 mm or +/- 0.2 % of set measuring range
2. Process temperature
-20 °C...+60 °C
(-4 °F...+140 °F)
3. Process pressure / max. overpressure limit
0.7 bar...3 bar abs
(10 psi ...44 psi)
4. Max. measurement distance
Sensor 1-1/2": 2 m (6.6 ft)
Sensor 2": 3.5 m (11 ft)
5. Main wetted parts
PP/EPDM
Field of application
The range of applications extends from monitoring levels in sewage treatment plants and process water tanks to applications for loading, storage and buffer tanks. FMU30 ultrasonic sensor offers proven software algorithms and all warning and alarm messages are shown on the four-line plain text display and guarantee fast remedy of problems. The envelope curve can also be shown on the display. As the analysis results are displayed directly on-site, this ensures quick and accurate error diagnostics.
Two-wire instrument for continuous non-contact level and flow measurement.
-Process connection: Thread
-Temperature: -20 to +60°C (-4 to +140°F)
-Pressure: +0.7 to +3bar (+10 to +44psi)
-Maximum measuring distance:
Sensor 1½" for liquids 5m (16ft) and for bulk solids 2m (6.6ft),
Sensor 2" for liquids 8m (26ft)and for bulk solids 3.5m (11ft)
-Blocking distance:
Sensor 1½" 0.25m (0.8ft),
Sensor 2" 0.35m (1.15ft)
-International explosion protection certificates
Benefits
1. Quick and simple commissioning via menu-guided onsite operation with four-line plain text display, 7 languages selectable
2. Envelope curves on the on-site display for simple diagnosis
3. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate
4. Non-contact measurement method minimizes service requirements
5. Installation possible from thread G 1½ or 1½ NPT upwards
6. Integrated temperature sensor for automatic correction of the temperature dependent sound velocity
Related Product Recommendation:
FMU30-1020/0 |
FMU30-AAHEAAGGF |
FMU30-11M0/0 |
FMU30-BBHEAAGGF |
FMU30-10A1/0 |
FMU30-AAHEABGHF |
FMU30-1082/0 |
FMU30-AAHGAAGGF |
FMU30-1DE9/0 |
FMU30-BBHGAAGGF |
FMU30-1E13/0 |
FMU30-BBHGABGHF |
FMU40-ANB2A2 |
FMU40-ARB2A2 |
FMU40-ANB2A4 |
FMU40-CRB2A2 |
FMU40-4NB2C2 |
FMU40-1NB2D2 |
FMU40-1RB2A2 |
FMU40-ARB1A2 |
Contact your exclusive customer service. | |
Contact Person : | Phil xv |
Job Title : | Sales manager |
Business Phone : | 008613559543328 |
WhatsApp : | 008613559543328 |
WeChat : | 008613559543328 |
Email : | sales05@ausenist.com |
Sales Allocation Arrangements, Handling Complaints and Suggestions | |
7 x 24 hours whatsapp | 008615959950473 |
Email : | candice@ausenist.com |