Indumax CLS54 Endress Hauser CLS54-ASMS012 Analog Conductivity Sensor with SPK CFB and Pt1000 Temperature Sensor
Detailed Product Description
Process Connection: | SMS SMS 2" | Additional Option: | Not Selected |
---|---|---|---|
Cable Connection: | 1 5m Fixed Cable | Temperature Sensor: | Pt1000 |
Net Weight: | 1.770 Kilogram | SPK: | CFB |
Highlight: | Endress Hauser CLS54-ASMS012,SPK CFB Analog Conductivity Sensor,Indumax CLS54 Analog Conductivity Sensor |
Endress+Hauser CLS54-ASMS012 Analog conductivity sensor Indumax CLS54
Field of application
The Indumax CLS54 inductive conductivity sensor protects all of your products and processes that must meet the strictest hygienic and sterile demands. Its outstanding performance combined with a unique hygienic design ensures highest safety and quality of your products.
Indumax CLS54 measures toroidal conductivity in hygienic food & beverage and life science applications, such as:
Phase separation of product/water and product/product mixtures in pipe systems
Control of CIP (cleaning in place) processes in the return channel
Concentration control in remaking of CIP cleaning agents
Product monitoring in pipe systems, bottling plants, quality assurance
Leakage monitoring
Its unique hygienic design is certified by EHEDG and 3-A.
SPECIFICATIONS
Measuring principle | Inductive |
Application | Food, beverage and pharmaceutical industries and in biotechnology. |
Characteristic | Specifically intended for use in hygienic applications and especially suitable for following applications: Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring. |
Measuring range | 100 µS/cm - 2000 mS/cm Cell constant k: 6,3 1/cm |
Measuring principle | Inductive conductivity measurement |
Design | Hygienic design with food-grade virgin PEEK body in jointless and creviceless design including all hygienic certifications. |
Material | In contact with medium: Virgin PEEK Surface roughness: Ra<0.9µm |
Process temperature | Process temperature: -10°C - +125°C (14°F - 257°F) Sterilisation: 150°C/5 bar (max. 60 min.) (302°F / 72.5 psi) |
Contact your exclusive customer service. | |
Contact Person : | Phil xv |
Job Title : | Sales manager |
Business Phone : | 008613559543328 |
WhatsApp : | 008613559543328 |
WeChat : | 008613559543328 |
Email : | sales05@ausenist.com |
Sales Allocation Arrangements, Handling Complaints and Suggestions | |
7 x 24 hours whatsapp | 008615959950473 |
Email : | candice@ausenist.com |
Write your message here and send it to us